RUN/STOP Button
Pressing RUN/STOP once will start the control process if the temperature controller is stopped, or stop the control process if the temperature controller is the run mode. If the temperature controller is running, “Heat” and “Cool” on-screen indicators will illuminate appropriay with the mode selected in the setup menu. The ‘Control Action’ selection is in the Advance Menu Gateway setup.
TUNE Button Pressing TUNE once will start the AUTO TUNE cycle. AUTO TUNING must be enabled in the setup menu for this key to function. ALARM Button In an ALARM situation, the display will display either “WARNING” or “ERROR”with corresponding warning or error. A “WARNING” will not stop the control process. An “ERROR” will stop the control process.MANUAL RESET mode: Pressing ALARM once will silence the audible alarm and clear the onscreen alarm message. If the alarm situation is present the “Alarm/Action Display” will remain illuminated. The alarm and on-screen message will not clear automatically, even if the system is no
longer in an alarm situation.AUTO RESET mode: Pressing the ALARM once will silence the audible alarm and clear the onscreen alarm message. If the alarm situation is still present, the “Alarm/Action Display” will remain illuminated. If the system leaves and alarm situation, the system will automatically silence the alarm and clear the on-screen alarm message.SELECT Button Pressing SELECT once will allow you to cycle through user-configurable control Set Points. The Set Point selected will be underlined. Set Points may be changed by using the UP and DOWN arrow keys.

MENU Button
The MENU button provides access to all user-configurable setup parameters of the Temperature Controller. Pressing this key once will scroll through parameter options. Pressing and holding this key will exit to the home screen, saving any changes made up to that point.UP, DOWN, LEFT Arrow Buttons The UP and DOWN arrow buttons will increase or decrease the value of the Set Point selected(underlined). Pressing the UP or DOWN arrow keys will increase or decrease numerical entries by
the least significant digit (i.e. 00.0 to 00.1, 1 to 2). Pressing and holding UP or DOWN arrow keys will increase or decrease numerical entries using an acceleration factor. For every ten units, the rate of acceleration will increase by a factor of ten. Pressing and holding UP and DOWN arrow keys will increase or decrease text entries without an acceleration factor. The LEFT arrow button allows you move backwards through the GENERAL SETUP MENU (GSM) and ADVANCED SETUP MENU (ASM). While in the ASM, you can move backwards to the first ASM screen, but cannot back into the GSM. To exit to the main screen from either menu, press and hold the MENU button.HEAT, COOL, AND TUNE When any of these modes are active they will have a block indicator on the display showing they are active. Example: When the control is in the heat mode and it is applying power to the heater

1. IEC power cord connection (see page 23 of user manual for additional cords)
2. Fuse
3. Heater/Cooler output (IEC 60320 on 230 volt, 5-15R on 115 volt) see page 24, 25 of user manual for optional country cord adapters.
4. Control power switch
5. Grip support bracket
6. Thermocouple, Type: J, K, N, R, S, T, B, and E (miniature 2 pin flat blade)
Installation
♦ Install control in safe operating area.
♦ Plug Heater/Cooler into the output connector, located on the back of the control.
♦ Connect input sensor into the proper connection input on control and place the thermocouple in the process that is being controlled. Install ferrite on lead wire of sensor. If further instruction is needed, see the user manual on installation of the ferrite.
♦ Plug supplied AC cord into the IEC connector, located on back of the control.

Operation Set up
♦ To enter the user-configurable setup press the MENU key from the system status screen.
♦ Use the MENU key to advance through each menu setting.
♦ Use the UP & DOWN key to make changes in each menu setting screen.
♦ Reference the flow chart (see pages 16 & 17 of manual) to have visual of the overall menu layout.
♦ When all settings have been made and saved the control will return to the System Status
screen.
♦ Set the Set Point temperature by pressing the select button one time. A line will appear under the Set Point value.
♦ Use the UP and DOWN arrow keys to change the Set Point value.
♦ Press the SELECT key one time when finished and the line under the Set Point will disappear.
♦ Press the RUN/STOP key when ready to start the heating/cooling operation.
♦ Running the TUNE feature is recommended when running a new process variables.

Tune Operation
♦ Set the process temperature as instructed in the operation setup.
♦ Verify that the Auto Tune feature is enabled in the menu settings.
♦ From the System Status screen set the Set Point temperature.
♦ Press the TUNE button and the indicator showing Tune will have be illuminated on display.
♦ The Set Point value isn’t changeable after the Tune process has started. The value is locked until the Tune process is complete or aborted by the user.
♦ Stopping the Tune operation prior to it finishing will cause the PID settings to be returned to factory default values.
♦ PID values will be saved in non-volatile memory.

Control Sensor
Proper placement of the sensor can eliminate many problems in the operation of the system. The probe should be placed so that it can detect any temperature change with little thermal lag. In a process that requires fairly constant heat output, the probe should be located close to the heater. In processes where heat demand is variable, the probe should be located close to the work area. Experimenting with probe location will provide optimum results for the users specific application.

免責(zé)聲明

  • 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡(luò)有限公司-化工儀器網(wǎng)合法擁有版權(quán)或有權(quán)使用的作品,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權(quán)使用作品的,應(yīng)在授權(quán)范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關(guān)法律責(zé)任。
  • 本網(wǎng)轉(zhuǎn)載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點和對其真實性負(fù)責(zé),不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個人從本網(wǎng)轉(zhuǎn)載時,必須保留本網(wǎng)注明的作品第一來源,并自負(fù)版權(quán)等法律責(zé)任。
  • 如涉及作品內(nèi)容、版權(quán)等問題,請在作品發(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。
企業(yè)未開通此功能
詳詢客服 : 0571-87858618
性猛交╳xxx乱大交| 九九热这里只有精品视频| 久久久国产一区二区三区四区小说| 国产黄色视频| 成人免费电影网站| 国产一起色一起爱| 欧美大屁股xxxxhd黑色| 97精品一区二区视频在线观看| 两只奶头被老头吸肿了| 精品国产乱码一区二区三区| 天堂AV无码一区二区三区| 麻豆人妻少妇精品无码专区| 午夜理论2019理论无码| 丰满大爆乳波霸奶| 亚洲av永久无码天堂网毛片| 国产成人一区二区三区在线| 国产精品自产拍高潮在线观看| 汤芳人体艺术| 他扯掉她的内裤猛地挺进她| 无人区在线观看免费观看| 快穿名器高h喷水荡肉爽文| 亚洲一区精品无码色成人| 超碰CAO已满18进入| 精品综合久久久久久888蜜芽| 亚洲欧洲精品a片久久99| 可播放的男gary| 风韵犹存岳厨房激情| 欧美人与动性XXXXBBBB| 国产精品国产亚洲区艳妇糸列短篇| 秘密爱在线观看| 特黄把女人弄爽又大又粗| 张筱雨两腿玉门打开图| 少妇荡乳情欲办公室456视频| 日韩国产成人无码av毛片| 亚洲av无码国产综合专区| 亚洲AV影院一区二区三区| 亚洲中文无码亚洲人成软件| 亚洲精品久久久口爆吞精| 久久久精品久久久久久96| 粗大的内捧猛烈进出少妇视频| 三个寡妇干柴烈火|